Q Exactive HF

Q Exactive HF




Categorías: , .
Share
  • Descripción

    The Thermo Scientific™ Q Exactive™ HF hybrid quadrupole-Orbitrap mass spectrometer features an ultra-high-field Orbitrap analyzer which doubles its speed and resolution – more samples run and amazing data quality. Built on the proven performance of the Q Exactive Plus platform, the Q Exactive HF mass spectrometer utilizes the same active beam guide technology and advanced quadrupole design for very stable system operation and exceptional analytical performance. The Q Exactive HF mass spectrometer is designed for your toughest discovery and quantitation challenges where the combination of speed and highest performance are essential for the highest quality scientific results.

    Descripción

    UNIQUE FEATURES OF THE Q EXACTIVE HF

     

    • Characterize, quantify and confirm with unmatched confidence using the Q Exactive HF mass spectrometer.

     

    • Advanced Quadrupole technology featuring Thermo Fisher segmented HyperQuad.

     

    • Ultra-high-field Orbitrap analyzer which doubles its speed and resolution Resolving power up to 240,000.

     

    • Maximum scan speed 18 Hz.

     

    • Spectral multiplexing for enhanced duty cycle.

     

    • RF-Lens ion source for increased sensitivity.
    • Advanced Active Beam Guide intelligent ion beam management for high flux ion sources.
    • Intact Protein Mode for characterizing intact proteins with ease.

     

    Mass Range

    m/z 50-6,000

    Max Resolving Power

    240,000 @ m/z 200

    Max Scan Rate

    up to 18 Hz at resolution setting of 15,000 resolution @ m/z 200

    Mass Accuracy

    Internal: < 1 ppm RMS External: < 3 ppm RMS under defined conditions

    Dissociation

    In-Source CID, HCD

    Scan Functions

    FS, AIF, SIM, PRM, DIA, ddHCD

    Mass Range

    m/z 50-6,000

    Max Resolving Power

    240,000 @ m/z 200

    Max Scan Rate

    up to 18 Hz at resolution setting of 15,000 resolution @ m/z 200

    Mass Accuracy

    Internal: < 1 ppm RMS External: < 3 ppm RMS under defined conditions

    Dissociation

    In-Source CID, HCD

    Scan Functions

    FS, AIF, SIM, PRM, DIA, ddHCD

    Quad IsolationStep-less from full mass range down to 0.4 amu

     

    Polarity Switching

    One full cycle in < 1 sec (one full scan positive mode and one full scan negative mode at resolution setting of 30,000)

    Multiplexing

    Up to 10 precursors/scan

    Analog Inputs

    One (1) analog input (0 – 1 V) One (1) analog (0 – 10 V)